The 3rd International Conference on Electrical Machines and Drives
Voltage Overshoots Mitigation in a Long Cable PWM-Fed Induction Machine Using dv/dt Filters
نویسندگان :
Mohammad Sedigh Toulabi
1
Shaahin Filizadeh
2
Liwei Wang
3
Mohammad Farahzadi
4
Reza Nasiri-Zarandi
5
Karim Abbaszadeh
6
1- Department of Electrical and Computer Engineering University of Windsor Windsor, Canada
2- Department of Electrical and Computer Engineering University of Manitoba Winnipeg, Canada
3- Department of Electrical and Computer Engineering University of British Columbia Kelowna, Canada
4- Faculty of Electrical Engineering University of Science and Culture Tehran, Iran
5- Electric Machines Research Centre Niroo Research Institute Tehran, Iran
6- Faculty of Electrical Engineering, K.N. Toosi University of Technology Tehran, Iran
کلمات کلیدی :
dv/dt filter،high-frequency modeling،induction machine،long cable،voltage overshoot
چکیده :
Significant voltage overshoots are observed in the input terminals of long cable pulse-width modulation (PWM)-fed induction machines, which can detrimentally impact the machine's lifespan and performance. To mitigate this concerning phenomenon, dv/dt filters consisting of R, L, and C elements are used in the circuit. In this paper, the high-frequency model of a long cable PWM-fed induction machine is established, incorporating the high-frequency models of the machine and long cable, as well as the pulses generated by the PWM converter and filters. Differential mode and common mode impedance measurements are employed to develop the high-frequency model of the induction machine, while short circuit and open circuit impedance tests are conducted to establish the high-frequency models of the long cable. The transmission line modeling approach is then utilized to incorporate the high-frequency modeled machine and long cable, enabling the prediction of voltage overshoots at the machine's terminal. Three distinct dv/dt filters are placed at the beginning, middle, and end of the long cable to mitigate the voltage overshoots in the terminal of the PWM-fed induction machine. Test results are presented for a 100 m cable, 2 hp machine fed by a PWM converter in the presence of the dv/dt filters, aiming to identify the appropriate filter location for minimizing voltage overshoots in the terminals of the machine.
لیست مقالات
لیست مقالات بایگانی شده
Design Considerations and Comparison of High-Speed Permanent-Magnet Motors for Flywheel Energy Storage Systems
Fariba Farrokh - Mohammed Jamal Mohammed - Ali Jafer Mahdi - Mohammad Farahzadi - Karim Abbaszadeh
A Hybrid PM Magnetic Gear With Efficient Utilization of Rare-Earth PMs
Mojtaba Malakooti Khaledi - Seyed Ahmadreza Afsari Kashani
Multi-Filter Deep Learning Framework for Partial Discharge Localization in Generator Stators
Mehdi Nourollahi - Mohammad Hamed Samimi - Arash Abyaz - Ahmad Kalhor
A Survey of Friction and Windage Losses Determination Methods of Induction Motors
Moslem Geravandi - Hassan Moradi
A Feasibility Study to Apply Frequency Response Analysis in Diagnosis of Power Generators
Mohammad Rahimi - Behnam Balali - Asghar Akbari Azirani - Peter Werle
A New Star-Type Rotor Topology In Radial Flux Magnetic Gear
Mojtaba Malakooti Khaledi - Seyed Ahmadreza Afsari Kashani - Mostafa Madanchi Zaj
Electromagnetic-Thermal Analysis of a Reluctance Magnetic Gear
Alireza Sohrabzadeh - Ashkan Shariati - Hossein Torkaman
A Comparative Review on Transformer Sound and Vibration Monitoring Methods Interpretation for Transformer Fault Prognosis Using Acoustic Signals
Ashkan Teymouri
Investigation study of Injecting Numerous DGs in IEEE 69 – bus Radial Networks Using Enhanced PSO and Ant Lion Optimization Algorithms
Ali Altahir - Ahmed Rahim Ali - Shamam Alwash - Murtadha Al-Kaabi
Design and Parametric Analysis of a New Segmented Consequent-Pole Permanent Magnet Machine
Mohammadreza Naeimi - Amir Ebrahimi Shohani - Mohammad Farahzadi - Fariba Farrokh - Karim Abbaszadeh - Johan Gyselinck
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.0.1