0% Complete
صفحه اصلی
/
The 3rd International Conference on Electrical Machines and Drives
Voltage Overshoots Mitigation in a Long Cable PWM-Fed Induction Machine Using dv/dt Filters
نویسندگان :
Mohammad Sedigh Toulabi
1
Shaahin Filizadeh
2
Liwei Wang
3
Mohammad Farahzadi
4
Reza Nasiri-Zarandi
5
Karim Abbaszadeh
6
1- Department of Electrical and Computer Engineering University of Windsor Windsor, Canada
2- Department of Electrical and Computer Engineering University of Manitoba Winnipeg, Canada
3- Department of Electrical and Computer Engineering University of British Columbia Kelowna, Canada
4- Faculty of Electrical Engineering University of Science and Culture Tehran, Iran
5- Electric Machines Research Centre Niroo Research Institute Tehran, Iran
6- Faculty of Electrical Engineering, K.N. Toosi University of Technology Tehran, Iran
کلمات کلیدی :
dv/dt filter،high-frequency modeling،induction machine،long cable،voltage overshoot
چکیده :
Significant voltage overshoots are observed in the input terminals of long cable pulse-width modulation (PWM)-fed induction machines, which can detrimentally impact the machine's lifespan and performance. To mitigate this concerning phenomenon, dv/dt filters consisting of R, L, and C elements are used in the circuit. In this paper, the high-frequency model of a long cable PWM-fed induction machine is established, incorporating the high-frequency models of the machine and long cable, as well as the pulses generated by the PWM converter and filters. Differential mode and common mode impedance measurements are employed to develop the high-frequency model of the induction machine, while short circuit and open circuit impedance tests are conducted to establish the high-frequency models of the long cable. The transmission line modeling approach is then utilized to incorporate the high-frequency modeled machine and long cable, enabling the prediction of voltage overshoots at the machine's terminal. Three distinct dv/dt filters are placed at the beginning, middle, and end of the long cable to mitigate the voltage overshoots in the terminal of the PWM-fed induction machine. Test results are presented for a 100 m cable, 2 hp machine fed by a PWM converter in the presence of the dv/dt filters, aiming to identify the appropriate filter location for minimizing voltage overshoots in the terminals of the machine.
لیست مقالات
لیست مقالات بایگانی شده
Neural Network-Based Prediction of AC Losses and Performance in High-Speed PMSM with Hairpin Winding
Mohammad Sepehr Zamani - Aghil Ghaheri - Ebrahim Afjei
Analysis of the Impact of Initial Rotor Position Estimation Error on the Speed, Current, and Startup Torque of Synchronous Reluctance Motors Considering Magnetic Saturation
Farzad Bodaghi - Hamidreza Pairo
A Multi-objective and Multi level Optimization of IPMSM Case Study Dynamometer
Ali Amini - MohammadSadegh KhajueeZadeh - Abolfazl Vahedi
شناسایی پارامترهای موتور القایی خطی دوطرفه اولیه بلند با استفاده از ترکیب روشهای یادگیری تقویتی و استراتژی تکاملی
امیرحسین قادری - رضا حقمرام
Comparative Study of Shield Placement to Mitigate the Stray Loss of Power Transformers Based on 3D-FEM Simulation
Mahsa Taghilou - Mojtaba Mirsalim - Morteza Eslamian - Ashkan Teymouri
Optimal Design of CSI-fed PMSM Integrated Motor Drive System Using Coupled Electromagnetic–Thermal Multiphysics simulation in Loop with Drive system
Hossein Azizi moghaddam - Reza Mirzahosseini
Fault-Tolerant Control and Torque Ripple Reduction of a Fully Modular Six-Phase Asymmetric Open-End Winding PMSM Drive
Abolfazl Halvaei Niasar
Analysis of a Novel L-Type Outer-Rotor Consequent-Pole Machine
Mohammadreza Naeimi - Karim Abbaszadeh - Johan Gyselinck
Active Equalization for an Integrated Bidirectional Electric Vehicle Charger Using a Hybrid Model Predictive and Reinforcement Learning Framework
Peyman Bayat - Pezhman Bayat
Dynamic Grid Search Optimization for ANFIS-Based Wind Turbine Control: Enhancing Efficiency and Adaptability
Ali Najari - Ava Zanir - Maryam Jabari - Mohammad Jabari
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0