0% Complete
صفحه اصلی
/
The 3rd International Conference on Electrical Machines and Drives
Voltage Overshoots Mitigation in a Long Cable PWM-Fed Induction Machine Using dv/dt Filters
نویسندگان :
Mohammad Sedigh Toulabi
1
Shaahin Filizadeh
2
Liwei Wang
3
Mohammad Farahzadi
4
Reza Nasiri-Zarandi
5
Karim Abbaszadeh
6
1- Department of Electrical and Computer Engineering University of Windsor Windsor, Canada
2- Department of Electrical and Computer Engineering University of Manitoba Winnipeg, Canada
3- Department of Electrical and Computer Engineering University of British Columbia Kelowna, Canada
4- Faculty of Electrical Engineering University of Science and Culture Tehran, Iran
5- Electric Machines Research Centre Niroo Research Institute Tehran, Iran
6- Faculty of Electrical Engineering, K.N. Toosi University of Technology Tehran, Iran
کلمات کلیدی :
dv/dt filter،high-frequency modeling،induction machine،long cable،voltage overshoot
چکیده :
Significant voltage overshoots are observed in the input terminals of long cable pulse-width modulation (PWM)-fed induction machines, which can detrimentally impact the machine's lifespan and performance. To mitigate this concerning phenomenon, dv/dt filters consisting of R, L, and C elements are used in the circuit. In this paper, the high-frequency model of a long cable PWM-fed induction machine is established, incorporating the high-frequency models of the machine and long cable, as well as the pulses generated by the PWM converter and filters. Differential mode and common mode impedance measurements are employed to develop the high-frequency model of the induction machine, while short circuit and open circuit impedance tests are conducted to establish the high-frequency models of the long cable. The transmission line modeling approach is then utilized to incorporate the high-frequency modeled machine and long cable, enabling the prediction of voltage overshoots at the machine's terminal. Three distinct dv/dt filters are placed at the beginning, middle, and end of the long cable to mitigate the voltage overshoots in the terminal of the PWM-fed induction machine. Test results are presented for a 100 m cable, 2 hp machine fed by a PWM converter in the presence of the dv/dt filters, aiming to identify the appropriate filter location for minimizing voltage overshoots in the terminals of the machine.
لیست مقالات
لیست مقالات بایگانی شده
A 12/7 Segmented Outer Rotor FSPM Motor with Improved Performance
Sadegh Mollaei Saghin - Aghil Ghaheri - Ali Harooni - Ebrahim Afjei
Rotor Topology Modification for Torque Enhancement in Synchronous Reluctance Motors via GA-Driven Parametric Optimization
Amirhassan Mirzaei - Mansour Rafiee
3D FE modeling and calculation of electromagnetic torque and eddy current loss in the end region of large synchronous generators
Moein Farhadian - Farshad KIANI - AmirAbbas Vahaj - Hamed Tahanian
Common Mode Voltage Reduction in PMSM Drives Using Model Predictive Control
Javad Amini - Reza Roshanfekr
آنالیز عددی و تحلیلی جداساز لرزه ای برای ترانسفورماتورهای قدرت
سعید بیگدلی - سعید نصیری
Analysis of the Cause of Abnormal Stator Winding Temperature Rise in a Gas Generator Using Log Data
Reza Khanlari - Fateh Vakili Mafakheri - Mehrdad Hamidian
Real-time temperature estimation of permanent magnets in a PMSM using a hybrid ANN and Lumped-Parameters Thermal Network
Mohammadreza Bagheri - Alireza Shokripour - Teymoor Ghanbari - Ebrahim Farjah
Analysis of a New Method for Reduction of Cogging Torque in a Direct-Drive In-wheel Flux Switching Motor
Rouhollah Rouhani - Alireza Rouhani - Seyed ehsan Abdollahi
Enhanced Predictive Current Control Strategy for PMSMs in the Presence of Parameter Uncertainty
AmirHossein Azad - Hossein Shateri
Fuzzy Logic Based Severity Detection of Broken Rotor Bars Using Current and Vibration Analysis
Hamidreza Aghaei - Ebrahim Nikghalb - Omid Khanzadeh
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0