0% Complete
صفحه اصلی
/
The 5th International Conference on Electrical Machines and Drives
Comparative Accuracy of IEC Ratio Approaches and Duval Triangle/Pentagon in Transformer Fault Diagnosis from DGA Data
نویسندگان :
Fateme Aliyari
1
Mohammad Hamed Samimi
2
Majid Sanaye-Pasand
3
1- university of tehran
2- university of tehran
3- university of tehran
کلمات کلیدی :
DGA،Fault classification،Power transformer،Dual Triangle،Dual Pentagon،IEC 60599
چکیده :
This paper evaluates the most common and established methods—IEC 60599, Duval Triangle, Duval Pentagon, and the 90th percentile gas population—for fault detection and classification of DGA results using 2,538 samples and the IEC TC 10 dataset. The aim was to investigate the fault classification accuracy of traditional DGA interpretation techniques using an extended, diverse dataset. The diagnostic efficacy of the methods discussed indicates that the Duval Triangle method achieves better fault classification performance. Furthermore, the accuracy of the methods in identifying both fault category and fault severity was analyzed. The results showed that despite its limited detection range and rigid zone boundaries, the IEC Ratio method provides higher certainty in the faults it identifies.
لیست مقالات
لیست مقالات بایگانی شده
Investigating the Impact of the Rotary Transformer’s Leakage Flux on the Accuracy of Brushless Synchros
MohammadAli Razavi - Farid Tootoonchian - Zahra Nasiri Gheidari
A LCC-LCC Converter with Near Constant Output Voltage for Autonomous Underwater Vehicles
Ahmad Siroos - Ebrahim Afjei - Xiaodong Liang - Alireza Sheikhi Fini
Novel Single-phase five-level current source CHB protection topology with SIC switches for induction motor
Amirhossein Ramezankhani - Amir Masoud Nouki - Farzad Bodaghi - Mohammadreza Arabshahi - Sobhan Mohammadian - Davood Arab Khaburi
Dual-Input/Dual-Output Axial-Flux Flux-Focusing Magnetic Gear: A New Approach for Symmetrical Torque Transmission
Ali Hosseini-Fard - Seyed Hamid Shahalami - Esmaeil Fallah Choolabi
A Fast Analytical Method for No-Load Air Gap Flux Density and Voltage Estimation in Large Synchronous Generators
Farshad Kiani - Hamed Tahanian
A Comparative Analysis of Two Different Types of Permanent Magnet Motors with Outer-Rotor Structure for Direct Drive Applications
Amir Ebrahimi Shohani - Mohammad Ardebili - Karim Abbaszadeh
Rotor Topology Modification for Torque Enhancement in Synchronous Reluctance Motors via GA-Driven Parametric Optimization
Amirhassan Mirzaei - Mansour Rafiee
Modeling and simulation of a Novel Actuator for Medium-Voltage Vacuum Circuit Breakers Based on PMSM Servo Drive
Shahin Mahdiyounrad - Hamid Ashrafi - Hamed Mohajeri
Electromagnetic Position Sensor Design by the Aid of Printed Circuit Board
Arman Nooruzpour - Ramin Alipour-Sarabi
Investigation of a Biased-Flux Halbach-Configured Permanent Magnet Motor
Sara Beyrami Bigdeli - Mohammad Judaki - Ali Rahimi Meydani
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.6.0