The 5th International Conference on Electrical Machines and Drives
Impact of Bridge and Linear De-Energized Tap Changer on Transformer Short-Circuit Impedance: An Analytical Approach
نویسندگان :
Mahsa Taghilou
1
Mojtaba Mirsalim
2
1- Department of Electrical Engineering Amirkabir University of Technology
2- Department of Electrical Engineering Amirkabir University of Technology
کلمات کلیدی :
De-energized tap changer،impedance،linear DETC،bridge DETC،axial magnetic field،radial magnetic field
چکیده :
De-energized tap changers (DETCs) offer a cost-effective means of voltage regulation in transformers with steady load conditions, serving as an alternative to on-load tap changers (OLTCs). Unlike separate DETC units, integrated DETC designs are embedded into the main winding structure, where the introduction of air gaps results in non-uniform ampere-turn distributions. This structural difference alters the impedance profile, increasing radial leakage reactance. Elevated impedance can enhance eddy current and stray losses, thereby raising overall load losses and operating temperatures, which may necessitate additional cooling provisions and impact long-term reliability. This paper investigates the impact of integrated linear and bridge DETC configurations on transformer impedance. An analytical modeling framework is proposed for both configurations, with impedance behavior evaluated to highlight performance and design implications.
لیست مقالات
لیست مقالات بایگانی شده
Robust sate feedback control of DC-DC boost converter using Legendre polynomials
Soroush Sarmad - Saeed Khorashadizadeh
Groundbreaking Application of the Corona-Virus Search Optimizer Algorithm for Resilient Speed Control and Stability Assessment of Direct Current Motors Under Uncertain Conditions
Peyman Zare - Amir Mohammadian - SeyedJalal SeyedShenava - Babak Mohamadi
A data-driven load shedding method based on generative adversarial networks considering missing data and unlearned fault
Nazanin Pourmoradi - Sasan Azad - Mohammadtaghi Ameli
A Numerical Method for Prediction of Standard Partial Discharge Test Performance of An Open-Ventilated Dry-Type Transformer at Design Stage
Mohammad Qumi - Mahdi Kazemiun - Mehdi Vakilian
Reduction of End Effect in Linear Variable Reluctance Resolver
Reza Ghorbanalizade - Ramin Alipour-Sarabi - Seyyed Ali Mirabbasi
Evaluation of Mechanical Fault’s Severity in Power Transformers by using Maximum Points of FRA Window Curves
Ahmad Vosoughi - Mohammad Hamed Samimi
Development of an ANFIS-Based Model for Condition Monitoring and Fault Diagnosis of Squirrel-Cage Induction Motors
Seyed Hamid Rafiei - Mansour Ojaghi
A delta-shape combined pole interior permanent magnet motor with lower permanent magnet cost
Amir Mahdi Dashtizadeh - Babak Ganji
Electromagnetic-Thermal Analysis of a Reluctance Magnetic Gear
Alireza Sohrabzadeh - Ashkan Shariati - Hossein Torkaman
Winding Configuration in High‑Frequency Current Transformers for Partial‑Discharge Detection in Power Cables
Amirhossein Dehghan Ahangar - Asghar Akbari Azirani - Mohammad Rahimi