The 3rd International Conference on Electrical Machines and Drives
Determination of the Permissible Range for Surface Resistance of the Outer Corona Protection Systems in High Voltage Electric Machines
نویسندگان :
Hamed Tahanian
1
Zeinab Sadat Sheikholeslami
2
Moein Farhadian
3
AmirAbbas Vahaj
4
Farshad Kiani
5
1- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
2- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
3- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
4- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
5- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
کلمات کلیدی :
insulation system،high voltage machines،outer corona protection،semiconductive coating،surface resistance
چکیده :
Outer Corona Protection (OCP) is one of the main components of the insulation system in high voltage machines. The main function of OCP is to eliminate high potential differences between the outer surface of the insulated bars (coils) and the grounded stator core in order to avoid surface discharge. To achieve this goal, the surface resistance of the OCP should be lower than a maximum value. However, there are some unpleasant consequences, such as vibration sparking and shorted core laminations, when the OCP is employed. To limit these side effects, other constraints on the maximum and minimum values of the OCP resistance should be considered. This paper tackles this issue from different aspects to provide the acceptable range for the OCP resistance. For this purpose, voltage and current at different positions on the OCP are calculated by analytical formula, taking into account the effects of capacitive currents of the bar insulation and magnetic flux of the stator yoke. Assumptions on the type and number of contact points between the OCP and stator core are made to consider the worst-case scenario. It is shown that the distance of these contact points changes the proper resistance range. Furthermore, the maximum allowed value of this distance is determined. The OCP resistance of a large turbine generator has been calculated by the proposed method. The satisfactory operation of this generator validates the calculation results.
لیست مقالات
لیست مقالات بایگانی شده
Reliability and Lifetime Analysis on Permanent Magnet Motors in Elevator: Case Study PMA-SynRM & IPMSM
Ali Amini - MohammadSadegh KhajueeZadeh - Abolfazl Vahedi
A Novel Non-Isolated DC–DC Converter with Hybrid Inductor–Capacitor Stages for High-Gain EV Application
Seyed Moein Mortezaie - Mohammad Sarvi
Comparative Accuracy of IEC Ratio Approaches and Duval Triangle/Pentagon in Transformer Fault Diagnosis from DGA Data
Fateme Aliyari - Mohammad Hamed Samimi - Majid Sanaye-Pasand
Diagnosis of Broken Rotor Bars in Induction Machines Using a Current Signature-Based Adaptive Extended Kalman Filter
Saeed Hajnayeb - Seyyed Meysam Seyyed Barzegar - Mohammad Hoseintabar Marzebali - Javad Keighobadi
تعیین تعداد برجستگی بهینه در رتور ریزالور رلوکتانس متغیر لولهای با استفاده از روش مدار معادل مغناطیسی
فاطمه زارع - فرید توتونچیان
CNN-Based Location Detection of Static Eccentricity in 5-X Resolver
Mahdi Emadaleslami - Farid Tootoonchian
پایش وضعیت روغن معدنی ترانسفورماتور بر اساس نسخه جدید استانداردIEC 60422-2024
سید عمیدالدین موسوی - مهدی بیگدلی
Axial Dual-Flux-Modulator Magnetic Gear Mitigating Yoke Flux Leakage
Aran Shoaei - Qingsong Wang
Optimization-Tuned Control of Wireless-Powered BLDC for LVADs under various Medical Conditions
Hawraa Ali - Ali Mahdi - Manal Nawir
Reducing Switching Losses in Brushless DC Motor Drive System by a Novel Soft Switching Inverter
Alireza Saffar Bahari - Esmael Fallah Choulabi - Seyed Hamid Shahalami
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 43.0.1