The 3rd International Conference on Electrical Machines and Drives
Determination of the Permissible Range for Surface Resistance of the Outer Corona Protection Systems in High Voltage Electric Machines
نویسندگان :
Hamed Tahanian
1
Zeinab Sadat Sheikholeslami
2
Moein Farhadian
3
AmirAbbas Vahaj
4
Farshad Kiani
5
1- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
2- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
3- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
4- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
5- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
کلمات کلیدی :
insulation system،high voltage machines،outer corona protection،semiconductive coating،surface resistance
چکیده :
Outer Corona Protection (OCP) is one of the main components of the insulation system in high voltage machines. The main function of OCP is to eliminate high potential differences between the outer surface of the insulated bars (coils) and the grounded stator core in order to avoid surface discharge. To achieve this goal, the surface resistance of the OCP should be lower than a maximum value. However, there are some unpleasant consequences, such as vibration sparking and shorted core laminations, when the OCP is employed. To limit these side effects, other constraints on the maximum and minimum values of the OCP resistance should be considered. This paper tackles this issue from different aspects to provide the acceptable range for the OCP resistance. For this purpose, voltage and current at different positions on the OCP are calculated by analytical formula, taking into account the effects of capacitive currents of the bar insulation and magnetic flux of the stator yoke. Assumptions on the type and number of contact points between the OCP and stator core are made to consider the worst-case scenario. It is shown that the distance of these contact points changes the proper resistance range. Furthermore, the maximum allowed value of this distance is determined. The OCP resistance of a large turbine generator has been calculated by the proposed method. The satisfactory operation of this generator validates the calculation results.
لیست مقالات
لیست مقالات بایگانی شده
Model predictive Control for Torque Ripple Reduction in Brushless DC Motor fed with five level CHB Inverter with low complexity
Zahra Emami - Abolfazl Halvaiee
Detection and Localization of Open-Circuit Fault in Two-Level Inverters Feeding PMSM
Sara Misaghi - Hadi Afsharirad
مدلسازی عیب مغناطیسزدایی در ماشین شارمحوری آهنربای دائم بدون هسته
فاطمه اسلامی - عارفه محبی - مصطفی شاهنظری
Multi-Filter Deep Learning Framework for Partial Discharge Localization in Generator Stators
Mehdi Nourollahi - Mohammad Hamed Samimi - Arash Abyaz - Ahmad Kalhor
Discrete Voltage Vector Modulation Based Model Predictive Torque Control with Reduced Switching Frequency for PMSM Drives
Hossein Bagheri - Siroos Hemmati - Shahram Karimi
Dynamic Modeling and Identification of Brushless Aircraft Generating System
Kamila Heshmati
A Novel High-Efficiency Multiple Output Single Input Step-Up Converter for Electric Vehicle Applications
Pedram Pakravan
تشخیص عیب میله شکسته در موتورهای القایی سهفاز با استفاده از طیف فرکانسی مولفه شعاعی شار پراکندگی بیرونی
علیرضا قائم پناه - علی مصلی نژاد - فرهاد حق جو
A Comparative Study on the Performance of Battery Impedance Models in State-of-Charge Estimation
Mohammad Mahdi Gholami - Alireza Rezazadeh
A review of modeling methods for axial flux induction motors
Mostafa Fatahi taba - Mojtaba Mirsalim
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 44.8.1